For Inquiry , Call us : +91 9836224820 , +918697635179 , Email : sales@truthbiomedical.com .
Best Quality , Fair Pricing. Exceptional Service ; These are the hallmarks under which TRUTH BIOMEDICAL STORE was established. At TRUTH BIOMEDICAL STORE, we provide clients with high quality medical equipment at unbeatable prices. Our business was founded in 2013 on the principles of fairness and selection, and we pride ourselves on our commitment to these founding principles to this day.
A medical equipment online store is a digital platform that specializes in selling a wide range of medical devices, instruments, supplies, and related products to healthcare professionals, institutions, caregivers, and individual consumers via the internet. Here are some key aspects of a medical equipment online store:
Extensive Product Catalog: An online medical equipment store offers a comprehensive selection of products covering various medical specialties and healthcare needs. This includes diagnostic equipment, surgical instruments, patient monitoring devices, mobility aids, therapy equipment, consumables, and more. The catalog is typically organized into categories and subcategories for easy navigation.
User-Friendly Interface: A well-designed online store features an intuitive and user-friendly interface that allows customers to browse, search, and filter products efficiently. The website should provide detailed product descriptions, specifications, images, and pricing information to help customers make informed purchasing decisions.
Secure E-commerce Platform: Security is paramount in an online medical equipment store to protect customer data and facilitate safe transactions. The website should use encryption technologies (e.g., SSL) to secure sensitive information such as payment details and personal data. Additionally, robust authentication and authorization measures help prevent unauthorized access to customer accounts.
Compliance and Quality Assurance: Reputable online medical equipment stores ensure that all products offered for sale comply with relevant regulatory requirements and quality standards. This includes sourcing products from reputable manufacturers, verifying certifications (e.g., FDA approval, CE marking), and conducting quality control checks to ensure product integrity.
Customer Support: Responsive and knowledgeable customer support is essential for addressing customer inquiries, providing product assistance, and resolving issues promptly. Online medical equipment stores typically offer multiple channels of communication, such as live chat, email, and phone support, to assist customers throughout the purchasing process.
Shipping and Delivery: Efficient shipping and delivery services are crucial for ensuring timely and reliable fulfillment of orders. Online medical equipment stores often partner with reputable shipping carriers to offer various shipping options, including standard, expedited, and same-day delivery, depending on customer preferences and requirements.
Return and Exchange Policies: Transparent and fair return and exchange policies provide customers with peace of mind when shopping online. Medical equipment stores should clearly communicate their policies regarding returns, exchanges, refunds, and warranties to facilitate hassle-free transactions and customer satisfaction.
Accessibility and Compatibility: Online medical equipment stores strive to ensure accessibility for customers with diverse needs, including those with disabilities. This may involve implementing accessible design features, providing alternative formats for content, and ensuring compatibility with assistive technologies.
Overall, an online medical equipment store serves as a convenient and accessible platform for healthcare professionals and consumers to access essential medical products and supplies, supported by robust e-commerce infrastructure, compliance with regulations, and excellent customer service.
Brand : TRUTH BIOMEDICAL
Features:
--3-part differentiation of WBC
--Double Chambers for WBC and RBC/PLT
--Throughout: 60 samples per hour
--Intelligent reagent management function: Reagent information and residual display
--Strong data management system
--Multilingual for option
--LCD with high resolution
--Bar code scanner (optional)
--Reagent alarm system (optional)
Technical Specifications:
21Parameter + 3Histogram
WBC, LYM#, MID#, GRA#, LY%, MID%, GR%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT,
P-LCR, P-LCC and Histogram for WBC, RBC, PLT
Method:
Coulter Principle (Electrical impedance) Colorimetry hemoglobin determination
Performance
Parameter
Linearity range
Precision (CV%)
WBC(109/L)
0.0-100.0
2.0(at 7.0)
RBC(1012/L)
0.00-9.99
1.5(at 5.00)
HGB(g/L)
0-300
1.0 (at 140)
PLT(109/L)
0-1000
4.5(at 250)
Parameter
Linearity range
Precision (CV%)
WBC(109/L)
0.0-100.0
2.0(4.0-10.0)
RBC(1012/L)
0.00-9.99
1.5(3.50-5.50)
HGB(g/L)
0-300
1.0 (110-160)
PLT(109/L)
0-1000
4.5(100-300)
Throughout
60 samples per hour
Menu
Review, Test, Maintenance, QC, Setup, Shutdown, Prime reagents, System diagnosis, Aperture rinse, Soak and Rinse, Calibration, instrument config Display
8” color touch screen display
Sample volume Predilute: 20µL Whole blood: 10µL Aperture Diameter WBC 80µM
RBC/PLT 70µM
Carryover
WBC≤1.5%, RBC, HGB<1.0%, PLT≤2%
Input / Output
1 RS232, 1 keyboard, Mouse
4 USB, LAN
Printout
Built-in thermal printer Operating Environment Temperature: 10-35℃
Humidity: ≤90%
Power Requirement
AC 100-240V 50/60Hz
Dimension
Instrument:440mm(H) x 350mm(W) x 440mm(D) Package: 570mm(H) x 520mm(W) x 600mm(D) Net Weight
Net:17kg Gross:21.8kg
Brand : TRUTH BIOMEDICAL
Features
1. Premium large touch screen (14 inch)
2. SMART-FLOW fluid patent technology
3. Accurate measurement for low value PLT
4. Low volume sample consumption
5. Low running cost
6. Easy to use
Technical Specifications
Principles
Tri-angle Laser Scatter, Flow Cytometry method, 3D Scattergram analysis, Impedance methodfor RBC and PLT counting, Cyanide free reagent for HGB test
Parameters
25 Reportable parameters:
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD,
RDW-CV, PLTMPV, PCT, PDW, PLCR, P-LCC, NEU%,
LYM%, MON%, EOS%, BAS%, NEU#,LYM#,MON#, EOS#, BAS#
1 3D Scattergram
3 Histograms(WBC/BASO, RBC, PLT)
4 Research parameter: ALY%, ALY#, LIC%, LIC#
3D Scattergram
3D holographic scattergram displays the accurate
5 part differentiation of WBC
Dual methods for BASO measurement
The first innovative analyzer combined the optical method of BASO(BASO-O) and impedance method of BASO(BASO-) together, it brings more reliable and stable measurement of BASO pathologic samples, and minimized the analysis failure.
Test Mode
CBC mode,CBC+DIFF mode
Venous whole blood, Capillary whole blood and Prediluted
Throughput
60 tests/hour
Printout
Can connect to external printer
Performance
Parameter
Linearity Range
Carry Over
CV
WBC
0-300*109/L
≤0.5%
≤2.0%
RBC
0-8*1012/L
≤0.5%
≤1.5%
HGB
0-250g/L
≤0.5%
≤1.5%
PLT
0-3000x109/L
≤1.0%
≤4.0%
Brand : TRUTH BIOMEDICAL
1. 8-inch, two kinds of configuration for choice: 3 Para, or 6 Para 3 Para: NIBP, SPO2, PR
6 Para: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
4. SPO2 can testing for 0.1% Weak;
5. RA-LL impedance Respiration;
6. Trend Coexist Display;
7. OxyCRG DyNamic View Display;
8. Bed to Bed view Display;
9. Networking capacity and nurse calling system;
10. Options of Central Monitoring System;
11. Built-in rechargeable battery 2200mAh;
12. 8" high resolution color TFT LCD display;
13. Large volume of tabular and graphic trends information storage and easy to recall;
14. Anti-ESU, anti- defibrillator;
15. Capture dynamic waveforms.
Brand : TRUTH BIOMEDICAL
1. 10.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
4. SPO2 can testing for 0.1% Weak;
5. RA-LL impedance Respiration;
6. Trend Coexist Display;
7. OxyCRG DyNamic View Display;
8. Bed to Bed view Display;
9. Networking capacity and nurse calling system;
10. Options of IBP, EtCO2, Central Monitoring System;
11. Built-in rechargeable battery 4400mAh;
12. 10.1" high resolution color TFT LCD display;
13. Large volume of tabular and graphic trends information storage and easy to recall;
14. Anti-ESU, anti- defibrillator;
15. Capture dynamic waveforms.
Brand : TRUTH BIOMEDICAL
Feature
1. 12.1-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
4. SPO2 can testing for 0.1% Weak;
5. RA-LL impedance Respiration;
6. Trend Coexist Display;
7. OxyCRG DyNamic View Display;
8. Bed to Bed view Display;
9. Networking capacity and nurse calling system;
10. Built-in rechargeable battery 4400mAh;
11. Large volume of tabular and graphic trends information storage and easy to recall;
12. Anti-ESU, anti- defibrillator;
13. Capture dynamic waveforms.
Technical Specification
ECG
Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
Heart Rate and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
Respiration
Method: Impedance between R-F (RA-LL)
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Measuring Range:
-Adult: 0 ~ 120 rpm
-Neo/Ped: 0 ~ 150 rpm
Resp. Alarm Range:
-High alarm range limit: 8~120 rpm
-Low alarm range limit: 6~120 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
NIBP
Method: Oscillometric
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Alarm Type: SYS, DIA, MEAN
Resolution Pressure: 1mmHg
Overpressure Protection
-Adult Mode: 297±3 mmHg
-Pediatric Mode: 240±3 mmHg
-Neonatal Mode: 147±3 mmHg
SpO2
Measuring Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy: ±2bpm
Temperature
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
IBP(optional)
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
-ART: 0 ~ 300 mmHg
-PA: -6 ~ 120 mmHg
-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
-P1/P2: -10 ~ 300 mmHg
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Standard Packing List
5-lead ECG cable (including RESP)
Adult finger SpO2 sensor
Adult NIBP cuff
NIBP extension tube
TEMP sensor
AC power adaptor
ECG electrodes
Operation instruction
Optional Function
Internal Recorder, IBP, EtCO2, Central Monitoring System, Touch Screen, VGA, Neonate SPO2
Brand : TRUTH BIOMEDICAL
Feature
1. 15.6-inch Six Standard parameters: ECG, RESP, NIBP, SPO2, 2_TEMP, PR/HR
2. 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
3. Efficient resistance to interference of defibrillator and electrosurgical cautery;
4. SPO2 can testing for 0.1% Weak;
5. RA-LL impedance Respiration;
6. Trend Coexist Display;
7. OxyCRG DyNamic View Display;
8. Bed to Bed view Display;
9. Networking capacity and nurse calling system;
10. Options of Internal Recorder, IBP, EtCO2, Central Monitoring System, Neonate SPO2
11. Built-in rechargeable battery 4800mAh;
12. 15.6" high resolution color TFT LCD display;
13. Large volume of tabular and graphic trends information storage and easy to recall;
14. Anti-ESU, anti- defibrillator;
15. Capture dynamic waveforms.
Technical Specification
ECG
Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 ch
Lead mode: 3 Leads (R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1 ch
Gain: ‘2.5mm/mV, ‘5.0mm/mV, ‘10mm/mV, ‘20mm/mV, auto
Heart Rate and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy: ± 1% or ± 1bpm, which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
-Monitor: > 105 dB
-Operation: > 105 dB
-Diagnosis: > 85 dB
Electrode offset potential: ±300mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 S after Defi.
ECG Signal Range: ±8 m V (Vp-p)
Bandwidth
-Surgery: 1 ~ 15 Hz
-Monitor: 0.5 ~ 35 Hz
-Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy: ±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
Respiration
Method: Impedance between R-F (RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Measuring Range:
-Adult: 0 ~ 120 rpm
-Neo/Ped: 0 ~ 150 rpm
Resp. Alarm Range:
-High alarm range limit: 8~120 rpm
-Low alarm range limit: 6~120 rpm
Resolution: 1 rpm
Accuracy: ±2 rpm
Apnea Alarm: 10 ~ 40 S
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,
120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
-SYS: 40 ~ 270 mmHg
-DIA: 10 ~ 215 mmHg
-MEAN: 20 ~ 235 mmHg
Pediatric Mode
-SYS: 40 ~ 200 mmHg
-DIA: 10 ~ 150 mmHg
-MEAN: 20 ~ 165 mmHg
Neonatal Mode
-SYS: 40 ~ 135 mmHg
-DIA: 10 ~ 100 mmHg
-MEAN: 20 ~ 110 mmHg
Resolution Pressure: 1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection
-Adult Mode: 297±3 mmHg
-Pediatric Mode: 240±3 mmHg
-Neonatal Mode: 147±3 mmHg
SpO2
Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %; 0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy: ±2bpm
Temperature
Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy: ±0.1°C
Actualization interval: about 1 Sec.
Average Time Constant:<10 Sec.
IBP (optional)
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
-ART: 0 ~ 300 mmHg
-PA: -6 ~ 120 mmHg
-CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
-P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5 uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy: ±2% or ±1mmHg, which great
Actualization interval: about 1 Sec
Standard Packing List
5-lead ECG cable (including RESP)
Adult finger SpO2 sensor
Adult NIBP cuff
NIBP extension tube
TEMP sensor
AC power adaptor
ECG electrodes
Operation instruction
Optional Function
Internal Recorder, IBP, EtCO2, Central Monitoring System, Neonate SPO2
Brand : TRUTH BIOMEDICAL
-The monitor adopts Ergonomic design and a compact structure to meet the needs of various parameter detections. It is suitable for adults, children, and newborns.
-Standard parameters: SpO2, 3/5 leads ECG, PR, HR, RESP, NIBP, 2*TEMP.
-Optional parameters: EtCO2, 12 leads ECG, 2*IBP.
-10/12/15 inch color LCD screen with optional touch screen and rotator knob.
-Capable to visualize 6 or more waveform. Support color coding for different waveform.
-28 ST segment analysis with ST trend with continuous display of ST value on screen.
-Multiple screen layout to view big font size in numeric and waveform.
-Trending facilities for up to 360 hours of both graphical & numerical along with event review facility for all parameters and full waveform disclosure facility.
-Different visual alarm with color coding and audible alarms for various parameters with three levels of
volume adjustment.
-Support HL7 protocol to access the central monitoring system, low-power design, extending battery life Configure, fanless design to ensure a quieter and cleaner environment Arrhythmia detection and analysis in various leads.
Brand : TRUTH BIOMEDICAL
Features
Cold-light source with high luminosity, long shelf life
Innovative light sensor, high sensitivity
Automatic calibration improves accuracy
Standard RS232 interface for connect with external computer
Storage of 2,000 testing results
Specification
Testing Principles: The reflective photometer reads the color on the strip to calculate the concentration of each testing item and output a semi quantitative analysis result.
Test items: GLU, BIL, SG, pH, KET, BLD,
PRO, URO, NIT, LEU, VC
Wavelength: 470nm, 525nm, 625nm
Stray light :Relative intensity ≤ 1%
Linearity :Linear correlation coefficient ≥0.995
Repeatability : Coefficient of variation CV ≤ 1%
Stability : During 8 hours of operation, Coefficient of variation CV ≤ 1%
Test throughput: 500 tests/hour
Language: English
Display: Large LCD touch screen, Resolution320×240
Printer: Built-in thermal recorder, paper width 57mm
Interface: Standard RS-232
Light source: Super-high brightness LED white light source, with 30,000 hours lifespan
ICU Ventilator
Brand : TRUTH BIOMEDICAL
Technical Specifications
PARAMETER
SPECIFICATION
Display Mode
10.4-inch High-definition TFT color LCD screen display
Ventilation Mode
VCV, PCV, SIMV, PSV, PSV+SIMV, CPAP
Ventilation Function
PEEP, SIGH, standby, IP, IRV
Ventilation Parameters
Tidal Volume
20~1800 ml
Rate
1~120 bpm
SIMV Rate
2~20bpm
I:E
4:1~1:8
Inspiratory Trigger Pressure
-10~10 cmH2O
Flow Trigger Sensitivity
1-20L/min
PEEP
0~25 cmH2O
Pressure Control
3~50 cmH2O
Pressure Limit
5~60 cmH2O
Pressure Slope
1~10 gear
Flow Rate Setting
1~10 gear
Expiratory Trigger Sensitivity
10%~90%
Time Control
1~10s
SIGH
1.5 times the inspiratory time(60-120 times adjustable)
Inspiratory Platform
0~50%
Oxygen Concentration
21%~99%
Parameters for Ventilation Monitoring
VI tidal volume, VE tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity , pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure –volume loop
SECURITY ALARM SYSTEM
Oxygen Concentration Alarm
Upper Limit Setting Range
21%~99%
Low Limit Setting Range
18%~80%
Airway Pressure Alarm
Upper Limit Setting Range
5~60 cmH2O
Low Limit Setting Range
0~50 cmH2O
Minute Ventilation Volume Alarm
Upper Limit Setting Range
1~20L/min
Low Limit Setting Range
0~19L/min
Tidal Volume
Upper Limit Setting Range
10~1800ml
Low Limit Setting Range
0~1700ml
Respiratory Rate
Upper Limit Setting Range
10~99bPm
Low Limit Setting Range
0~50 bPm
Sustained High-pressure
Alarm
It will give alarm when stress have consistently been higher than 30 cmH2O.
Suffocation Alarm; Gas Shortage Alarm; Low Pressure of Oxygen Alarm; Low Pressure of Air Alarm; Power Alarm; Intubation off Alarm; Battery Voltage Alarm
Power
AC220V, 50Hz.
UPS, Storage Battery
Manipulator
MEDICAL ULTRSOUND MACHINE
SERIES : Digital Mantra 1004
Brand : TRUTH BIOMEDICAL
• 15-inch LCD display with up and down adjustment
• Optional 3D or 4D
• Compact fuselage, easy to move
• Flexible lifting panel
• Trapezoidal imaging
• Reverse Tissues Harmonic Imaging
• Two-level backlit keyboard, more convenient to operate
• lt can meet the needs of clinical diagnosis and improve the confidence of diagnosis.
• Broadband frequency shift harmonic imaging
• It can effectively reduce noise and improve contrast resolution
• Intelligent speckle noise suppression imaging
Intelligent speckle noise suppression technology can intelligently identify different tissue information in different spatial dimensions, inhibit the display of speckle noise edge information, and make the image more exquisite
• Intelligent space composite imaging
Intelligent spatial composite imaging technology, through spatial multi-angle deflection scanning, updates echo signals received from different angles in real time, continuously updates fusion imaging, effectively inhibits random noise and clutter signals under the premise of guaranteeing the temporal resolution, enhances the target organization display, and improves the spatial resolution of the image.High resolution medical LCD.
Main Functions:
Having a full digital beam forming technology
Scanning mode: Convex array, lumen, high-frequency linear array, phased array;4D probe(Optional)
Probe parameters
* Convex: Center frequency 3.5MHz (range: 2-6MHz)
* Linear: Center Frequency 7.5MHz (Range: 5-12MHz)
* High-frequency Linear : Center frequency 9MHz (range: 5-13MHz)
* Cavity probe(TVS): center frequency 6.5MHz (range: 5-10MHz)
* Micro-convex: center frequency 3.5MHz (range: 3-6MHz)
* High-frequency micro-convex probe: the center frequency of 5MHz (range: 4-8MHz)
* Phased array probe: 3 MHz (range: 2-5MHz)
* 4D probe : Center frequency 3 MHz (range: 2-5MHz)
The performance requirements of Doppler spectrum mode
a). The color ultrasonic at the color Doppler spectrum mode should comply with the provisions of the;
b). Blood flow speed reading error should comply with the provisions of the table2.3;
c). Pulse wave Doppler mode sampling area cursor position should be accurate;
Table 2.3 at the color blood flow imaging mode the performance of the probe
Doppler model
Phased array
Convex array
Cavity
Linear array
Investigation depth at Color blood flow model
≥90mm
≥100mm
≥40mm
≥50mm
Investigation depth at Doppler spectrum model
≥90mm
≥100mm
≥40mm
≥50mm
Blood flow speed reading error
≤±15%
Displayer: 15 inch LCD color display;
Running hours: ≥8h;
Input power: ≤320V;
Host weight: about 7 kg;
Host appearance size:380 ×212×390(length × width × height) (mm3).
Series : Digital Mantra 1005
Brand : TRUTH BIOMEDICAL
Detailed Information
he whole body applies the color ultra, the intelligence operation flow, the humanization exterior view design, and the intimate man-machine interaction is an organic whole. Home screen 21.5 inches medical HD display; Touch screen 14-inch oversized touch screen; The probe 4 interface is fully activated and the storage card slot is freely combined; Custom buttons can be freely assigned according to the doctor’s habits. High quality clinical performance: space composite imaging, one-button image solution to greatly improve work efficiency, the use of real-time volume probe, and mainstream imaging technology, further shorten the diagnostic distance. Stable and efficient: deeply optimized Windows operating platform and integrated high-performance and low-power industrial control solutions. User-friendly operation design: touch screen fast navigation, reduce button contact and press, simplify operation steps, reduce user fatigue to a greater extent, and improve the work efficiency of doctors. High-cost performance: all software functions are opened once, and additional consumption is refused; Full service tracking.
Technical Specification
Brief description of the main and wheel color type Doppler ultrasound
A fully digital color Doppler ultrasonic computer is a typewriter
Ultrasonic host operating system: Windows operating system
Programs:
Belly, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal system
Probes:
Convex Probe, Transvaginal Probe, Linear Probe, Micro Propellant Probe, Cardiology Probe, 4D Surface Probe
Programs and Reports:
Support for stomach, midwifery, gynecology, heart, urology, small organs, superficial, blood vessels, pediatrics, etc.
carotid intima measurement thickness (IMT)
Automatic spectral shell measurement
Full digital transmission and reception of ray synthesizer
Color Doppler (C)
Impulse Doppler PW
Coherent contrast image) CCI
Doppler visualization of a continuous wave) CW
B / C / D Three synchronous images in real time
Power Doppler (PDI)
Doppler Tomography Direct Power D DPDI
Picture of M mode
Visualization of anatomical mode M
Color Doppler in M mode
Electrography
Fabric Doppler TDI
Visualization of Deformation Rate (SRI)
Fabric Harmonic Tomography) THI
Fusion of Harmonic Imagery I FHI
Speculation reduces the image (SRI
Panoramic images
Displacement display
Trapezoidal visualization
Adaptive speed optimization
Free hand 3D
3D real-time images / 3D / 4D
DICOM3.0
Monitor: ≥21.5 inches, ultrasonic high definition display
≥10.4-inch touch screen
Physical Clipboard: Save the image on the left side of the screen, which can be directly saved or deleted.
Series : Digital Mantra 1007
Brand : TRUTH BIOMEDICAL
Detailed Information
Technical Specifications
⦁ Product Name: Color Doppler Machine
1.1 Structure type: Trolley type
⦁ Purpose and applications:
2.1 To meet the basic hospitals in the abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, neonatal, muscle, physical examination and other inspections and diagnosis.
⦁ Main specifications and system overview:
3.1 Operating system: Windows 10
3.2 Pulse Wave Doppler
3.3 Directional Energy Doppler
3.4 Real-time triple synchronization
3.5 Spatial Composite Imaging ☆
3.6 Tissue Harmonic Imaging
3.7 2B/4B Imaging
3.8 Support system languages: English, French, Russian, Spanish .
3.9 Standard monitor size: 21.5 inch, high-definition medical grade LCD display
3.10 Integrated clipboard: display the saved images at the bottom of the screen, which can be directly transferred or deleted
3.11 With on-site upgradeable functions
3.12 Preset conditions: For different inspections, preset inspection conditions for optimized images, reducing adjustments during operation, and commonly required external adjustments and combined adjustments
3.13 Probe ports: 3 active ☆
3.14 Trapezoidal Imaging ☆
3.15 One-key auto optimization
Multiple frequency of different probes:
Convex probe: frequency 2.0MHz, 2.5MHz, 3.0MHz, 3.5MHz, 4.0MHz, 5.5MHz, H4.0MHz, H5.0MHz, eight-segment frequency conversion (depth 30-255mm)
Linear probe: Frequency: 6.0MHz, 7.5MHz, 8.5MHz, 10.0MHz, 12.0MHz, H10.0MHz, six-segment frequency conversion (depth 20-128mm)
Trans-vaginal probe: Frequency: 4.5MHz, 5.0MHz, 6.0MHz, 6.5MHz, 7.0MHz, 9.0MHz, H8.0MHz, seven-segment frequency conversion (depth 30-156mm)
Micro-convex probe (R15): frequency 4.5MHz, 5.0MHz, 6.0MHz, 6.5MHz, 7.0MHz, 9.0MHz, H8.0Mhz, seven-segment frequency conversion (depth 30-111mm)
Rectal probe: frequency 4.0MHz, 6.5MHz, 9.0MHz, H8.0Mhz, four-segment frequency conversion (depth 20-110mm)
Phased array probe: frequency 2.0MHz, 2.5MHz, 3.0MHz, 3.5MHz, 4.0MHz, 5.0MHz, H3.0MHz, H4.0MHz, eight-segment frequency conversion (depth 100-244mm)
L25 linear probe: frequency 6.0MHz, 7.5MHz, 8.5MHz, 10.0MHz, 12.0MHz, H10.0MHz, six-segment frequency conversion (depth 20-110mm)
2D mode
⦁ Gain: 0-100, single step 1, visible and adjustable
⦁ TGC: 8 segment adjustable
5.3 Dynamic range: 20-280dB, 20 levels visible and adjustable
5.4 Pseudo color: 12 kinds, visible and adjustable
5.5 Sound power: 5%-100%, single step 5%, visible and adjustable
5.6 Body mark: 17 kinds
5.7 Number of focus: max 6
5.8 Gray Scale: 0-7, visible and adjustable
5.9 Filtering: 0-4
5.10 Scanning range: 50%-100%
5.11 Frame related: 0-4, visible and adjustable
5.12 Real-time display of 14 parameters such as sound power, probe frequency, dynamic range, pseudo color, gray scale, etc., which are adjustable
5.13 Scanning line density: high, medium and low adjustable
5.14 Noise reduction: 0-14
⦁ Color Imaging Mode:
6.1 Color deflection: available
6.2 Color frame related: 0-12 levels, visible and adjustable
6.3 Color map: 0-7 levels, visible and adjustable
6.4 Color flip: adjustable
6.5 B/C split screen synchronous display function: available
6.6 Color baseline: 11 levels, visible and adjustable
6.7 Color line density: high and low adjustable
6.8 Wall filter: 0-5 level adjustable
⦁ Pulse Wave Doppler Mode
7.1 Sampling volume angle correction: -80°~80° adjustable
7.2 Sampling volume: 0.5mm-20mm visible and adjustable
7.3 Frequency: 2.5MHz and 3.0MHz visible and adjustable
7.4 Baseline: 9 levels adjustable
7.5 Pseudo-color spectrum: 0-5
7.6 Display layout: 4 kinds, visible and adjustable
7.7 Pseudo-color: 6 kinds adjustable
*7.8 Speed scale: 32.8-328cm/s (varies on different probes)
7.9 Spectrum envelope function: real-time automatic spectrum envelope, manual spectrum envelope and other modes are available, the system automatically analyzes and displays: PSV, EDV, RI, PI, S/D, ACC, HR and other data
7.10 Grayscale: 0-7
7.11 Wall filter: 0-20
7.12 Dynamic range: 10-95dB, single step 5
7.13 Noise reduction: 0-10
7.14 Volume: 0-100
Series : Digital Mantra 1008
Brand : TRUTH BIOMEDICAL
Color Doppler Ultrasound Machine
(Double Screen) with 2 Probe Convex and Linear
Specification:
1 Summary of main specifications and system of Trolley 4D color Doppler ultrasound
1.1 Trolley type all digital color Doppler ultrasonic mainframe
1.2 Ultrasonic host operating system: Windows7 operating system
1.3 Spectrum pulse Doppler
1.4 Direction energy Doppler
1.5 Real time three synchronization
1.6 Space composite imaging: the requirement is 3 level, visual adjustable.
1.7 Organized harmonic imaging technology
1.8 4B imaging mode
1.9 One key intelligent optimization
1.10 Support multilingual user interface
1.11 Monitor: 19 inches, high-definition LED.
1.12 Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted.
1.13 The system has the function of on-the-spot upgrade
1.14 Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation.
1.15 Support real-time 3D imaging function
1.16 Language: English/Russian/Spanish/French/Arabic/
Vietnamese/Portuguese/Indonesian
1.17 The probe interface is 4
2 Probes:
2.1 Convex probe: 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz,
2.2 Linear probe: 6.0MHz/6.5MHz/7.5MHz/10.0MHz/12.0MHz,
2.3 Trans-vaginal probe: 5.0MHz/6.0MHz/6.5MHz/7.5MHz/9.0MHz,
2.4 R11 Micro convex probe: 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz
6.0MHz/7.5MHz/10MHz,
2.5 R15 Micro convex probe: 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz/
6.0MHz/7.5MHz/10MHz,
2.6 Phased array probe: 2.1MHz/3.0MHz/3.5MHz/4.0MHz/5.0MHz,
2.7 4D Volume probe: 2.0MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz,
2.8 The above probe has harmonic frequency (providing picture proof).
3 Two-dimensional imaging mode
3.1 Gain: 0-100, step 2 visible adjustable
3.2 TGC: 8 segment adjustable
3.3 Image optimization: visible and adjustable over 6 levels
3.4 Dynamic range: 0-270dB 15 level visual adjustable
3.5 False color: 7, visible and adjustable
3.6 Smooth treatment: 8, visible and adjustable
3.7 Edge enhancement: 8, visible and adjustable
3.8 Sound power: 0-15, step 7%, visible adjustable
3.9 Display depth: ≥ 320mm,
3.10 Maximum focus number: 4 focal points, which can be moved throughout the whole process.
3.11 Scan line density 256 visible tunable
3.12 Gray scale: 1-16 level visible visible and adjustable
3.13 Filtering, 3 kinds
3.14 Scanning range, 50%-100%
3.15 Frame correlation, 0-4 level, visible and adjustable
3.16 The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 14 parameters can be adjusted
4 Color imaging mode
4.1 Color frequency: 7 frequency conversion, visible adjustable
4.2 Color deflection: equipped with
4.3 C afterglow 8, visible and adjustable
4.4 Color map: 7, visible and adjustable
4.5 Color reversal: adjustable
4.6 B/C split screen synchronous display function: equipped with
4.7 Color baseline: 7, visible and adjustable
4.8 Color line density: adjustable
5 Spectrum Doppler mode
5.1 Sampling volume angle correction: -80 degree to 80 degree adjustable
5.2 Sample volume: 0.5mm-48mm visually adjustable
5.3 Frequency: ≥ 5, visible and adjustable
5.4 Baseline: 7 adjustable
5.5 Smooth: 8 files can be adjusted
5.6 False color: 7 kinds of adjustable
5.7 Maximum display blood flow measurement speed 25m/s, minimum resolvable blood flow measurement speed: 0.1mm/s
6 Measurement and analysis function:
6.1 General measurement distance, area, angle, time, slope, heart rate, velocity, acceleration, spectrum tracing, resistance index / plasticity index, etc.
6.2 Professional software package: abdomen, volume, ratio, obstetrics and Gynecology, small organs, carotid artery, Urology, orthopedics, peripheral blood vessels, heart.
7 Graphic and text management system
7.1 Host built in ≥120G solid state hard disk to start fast and stable
7.2 Movie playback: 600 frames
7.3 Internal patient file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.
7.4 The type of report is 3
7.5 One key fast report graphic and text management
8 Interface
8.1 USB interface: 4
8.2 HDMI interface: 1
8.3 RJ-45 interface: 1
8.4 VIDEO interface: 1
8.5 Grounding wire interface: 1
Series : Digital Devine 1001
Brand : TRUTH BIOMEDICAL
Detailed Information
Specifications
1 System overview:
1.1 Technical specifications:
1.1.1 1-25MHz High frequency system
1.1.2 Full digital broadband beam former
1.1.3 Digital high resolution B imaging
1.1.4 Color Doppler imaging
1.1.5 Power Doppler imaging
1.1.6 Direction power imaging
1.1.7 Gray-scale M Imaging
1.1.8 Color M Imaging
1.1.9 Pulsed doppler imaging
1.1.10 Continuous doppler imaging
1.1.11 Tissue doppler Imaging
1.1.12 Tissue velocity Imaging
1.1.13 Tissue velocity Imaging by M mode displaying
1.1.14 Two and three synchronization image display
1.1.15 B and color display in real time
1.1.16 Tissue harmonic imaging, reverse harmonic imaging
1.1.17 Spatial compound imaging technology
1.1.18 Speckle noise suppression technology
1.1.19 Trapezium imaging
1.1.20 B/CF/PW independent deflection
1.1.21 Grayscale inversion mode
1.1.22 One-click Automatic optimization
1.1.23 Zoom to full screen
1.1.24 Real-time local zoom
1.1.25 Focus ≥ 8
1.1.26 Dynamic range: 30dB~280dB, step by 2dB
1.1.27 High quality three dimensional / four dimensional imaging
1.1.28 Ultrasonic tomography
1.1.29 Render mode: maximum, minimum, X mode, smoothing mode, surface mode
1.1.30 Arbitrary removal of editing (Magic cut )
1.1.31 Optional volume ultrasound tomography
1.1.32 Optional panoramic imaging
1.1.33 Optional full range M
1.1.34 Optional ECG
1.1.35 Optional Elastography
1.1.36 Optional ultrasound teaching instruction function, including anatomy diagram, scanning techniques, standard ultrasound image, scan method description
1.2 37 parameter adjustment for playback image
1.2.1 2D and M Mode 15 parameters: gain, dynamic range, TGC, reversal, filtering, automatic tissue optimization, rotate, flip vertical, grayscale maps, pseudo color, frames on average, spatial smoothing, spot removal, edge enhancement, M speed
1.2.2 CFM mode 8 parameters: color auto optimization, baseline, color conversion, color map, color threshold adjustment, flash color restrain, space smooth, color M speed adjustment
1.2.3 PW Mode 14 parameters: gain, baseline, angle correction, angle fast adjustment, frequency spectrum reversed, display format, refresh rate, inhibition, gray-scale map, pseudo color, dynamic range,frequency spectrum auto optimization, automatic tracking, sensitivity tracking
1.3 Measurement and analysis
1.3.1 General measurements
1.3.2 Vessel measurement package
1.3.3 Heart measurement package
1.3.4 Gynecological measurement package
1.3.5 Urological measurement package
1.3.6 Kidney measurement package
1.3.7 Measurement and analysis of doppler blood flow
1.3.8 Obstetric measurements and fetal growth curve table
1.3.9 Intelligent three-dimensional volume measurement
1.3.10 User-defined measurement
1.3.11 Real-time tracking and measurement of doppler spectrum
1.3.12 Automatic measurement of intima-media thickness(Auto IMT)
1.3.13 Optional automatic neck-transparent layer thickness measurement (Auto NT)
1.4 Integrated image storage (film) playback to reproduce and record management components:
1.4.1 Ultrasound image static and dynamic storage, playback to reproduce the original data
1.4.2 Images can be stored as PC Compatible formats
1.4.3 Medical records management components include: patient data, reports, images, stored, modified, retrieved, and printing
1.5 Support external workstation connection
2 Technical parameters and requirements:
2.1 System General features:
2.1.1 Display: ≥ 21 inch high resolution global color LED Display, can move updown left right
2.1.2 Touch screen: ≥ 13 inch high sensitivity capacitive touch panel
2.1.3 Probe connector: ≥ 4 activated no-pin type probe connector
2.1.4 Dedicated storage tank for endocavity probe
2.1.5 Heater coupling agent
2.1.6 The operations console can be up and down, left and right
2.2 Input / Output interfaces:
2.2.1 Network interface
2.2.2 Video output: DVI , S-video
2.2.3 USB Interface: ≥ 4
2.3 Image management and recording devices:
2.3.1 Hard drive capacity: ≥ 1T
2.3.2 Integration DVD
2.3.3 Support DICOM 3.0
2.3.4 Support one key fast store to U Disk, mobile hard disk
2.3.5 Support black/white and color video printer, and quick print function
2.4 Probe specifications:
2.4.1 Probe types: convex, linear, phased array, endocavity, volume
2.4.2 Linear array probe elements ≥ 192
2.4.3 Probe frequency on display, adjust on touch-screen
2.4.4 Probe frequency ≥ 4
Series : Digital Devine 1002
Brand : TRUTH BIOMEDICAL
Detailed Information
Applications: abdomen, gynecology and obstetrics, small organs, pediatrics, musculoskeletal, heart, blood vessels, lumen, urinary, breast, anesthesia, trauma, etc.
Input and output
Input: USB interface, Ethernet
Output: USB interface, DVI
Built-in integrated ultrasonic workstation, or external workstation
Image storage and record
1.1 DVD burn
2.2 Hard disc: ≥1T
3.3 Digital storage of static and dynamic images
4.4 Support USB storage function
4.5 Ultrasonic image archiving and case management system
4.6 Built-in DICOM 3.0 interface
Technical specifications
Monitor: removable from up and down, left and right, 19’’ LCD, 10’’ touch screen.
Operation console: movable from up and down, left and right
The pneumatic joint arm and lifting system are used
Probe specifications:
Available probes: convex, linear, phased array, endocavity, 4D volume probe.
Probe element: ≥128
Frequency: EPI, Visual adjustable base wave center frequency≥3 types, selectable frequency for color and Doppler images, independent variable frequency for 2D, color and Doppler.
Imaging mode
Convex probe: B/M/C/PW
Linear probe: B/M/C/PW
Endocavity probe: B/M/C/PW
Phase array probe: B/M/C/PW/CW
4D volume probe: B/M/C/PW/3D/4D
2D imaging parameters:
Gain adjustment: STC gain compensation≥8 segments, independent adjustment for B/M ; overall gain: 0-100dB, visual and adjustable.
Transmit beam focus: ≥7
Replay: grey images replay≥1000 frames
Scan lines: max. Density ≥512 lines
2D grey-scale imaging: ≥256
imaging rate: phase array probe, scan angle 85°, 18cm depth, at max. density, frame rate is ≥30 frames/sec
TYPE:TROLLEY NUMBER OF PROBE CONNECTOR:3 Spectral Doppler Imaging Parameters: PWD, CWD, HPRF Color: Silver And White Beam former Of Transmit:128-channelArray Element Of Probe:128
Series : Digital Devine 1003
Brand : TRUTH BIOMEDICAL
Additional Information
Specification
1 Application
It is mainly applied for ultrasonic diagnosis and scientific research of abdomen, obstetrics and gynecology, reproduction, blood vessels, heart, superficial tissue, breast, neonates, surgery, nerves, etc
2 Specification:
2.1 Include:
2.1.1 High resolution B imaging
2.1.2 Color doppler imaging (CDI )
2.1.3 Pulse wave doppler (PWD)
2.1.4 Continuous wave doppler (CWD)
2.1.5 Power doppler imaging (PDI)
2.1.6 Direction Power doppler imaging (DirPDI)
2.1.7 M mode imaging
2.1.8 Tissue doppler imaging
2.1.9 Tissue harmonic imaging
2.1.10 Pulse reverse harmonic imaging
2.1.11 Spatial composite imaging
2.1.12 Speckle noise suppression
2.1.13 Trapezoid imaging
2.1.14 Zoom in full screen
2.1.15 Real-time zoom
2.1.16 Smart one key imaging optimization
2.1.17 Static 3D imaging
2.1.18 Real-time 3D/4D imaging
2.1.19 Ultrasound tomography imaging
2.1.20 Magic cut: edit arbitrarily for 3D imaging
2.1.21 Render types:maximum, minimum, X ray display, surface, smoothness
2.1.22 Optional volume ultrasound tomography imaging
2.1.23 Optional multi angle M imaging
2.1.24 Optional color M mode imaging
2.1.25 Optional panorama imaging
2.1.26 Optional elastography imaging
2.1.27 Optional tissue velocity imaging
2.1.28 Optional tissue velocity M imaging
2.1.29 Optional gray-scale inversion imaging
2.1.30 Optional ultrasound learning and guide function: anatomical schematic diagram, scanning manipulation diagram, standard ultrasonic image, scanning method description, etc
2.2 *37 parameters adjustment when playback images:
2.2.1 Preset parameters: for different examined organs, the optimal image examination parameters are preset to reduce the adjustment during operation; users are permitted to define and save preset parameters
2.2.2 15 parameters on B and M mode: gain, dynamic range, TGC, image rollover, gray filter, tissue optimization, image rotation, left and right rollover, gray map, pseudocolor, frame average, spatial smooth, speckle rejection, edge enhance, M speed
2.2.3 8 parameters on CDI mode: color optimization, base line, color rollover, color map,color threshold adjustment, glitter rejection, spatial smooth, color M speed
2.2.4 14 parameters on PWD mode: gain, base line, angle revise,quick angle adjustment, spectrum rollover, display format, refresh rate, rejection, gray map, pseudocolor, dynamic range, spectrum optimization, auto tracking, sensitivity tracking
2.3 Measurement and analysis:
2.3.1 General measurement
2.3.2 Obstetrics measurement
2.3.3 Gynecology measurement
2.3.4 Vessel measurement
2.3.5 Urology measurement
2.3.6 Cardiac measurement
2.3.7 Abdomen measurement
2.3.8 User defined measurement
2.3.9 Doppler blood flow measurement
2.3.10 Small organs and superficial tissue measurement
2.3.11 Intelligent volume calculation
2.3.12 Auto doppler spectrum tracking and analysis
2.3.13 Optional auto measurement of intima-media thickness(Auto IMT)
2.3.14 Optional auto neck transparent layer thickness measurement(Auto NT)
2.4 Patient data management:
2.4.1 Patient data include: personal information, image, cine, report, etc
2.4.2 Patient data establishment, storage, playback, modification, retrieval and printing
2.4.3 Built-in integrate ultrasound workstation
2.4.4 Image storage format: PNG, JPEG, BMP, TIFF
2.4.5 Cine storage format: AVI, VRD
2.4.6 Optional DICOM 3.0
3 Technical parameters:
3.1 System general configure:
3.1.1 1-25MHz high frequency system platform
3.1.2 Full digital uwb beamformer
3.1.3 A/D sampling ≥ 14 BIT
3.1.4 Monitor: ≥21 inch, high resolution LED color monitor that can be moved up, down, left and right
3.1.5 Touchscreen: ≥10 inch, high sensitivity capacitive touchscreen
3.1.6 Control panel: ergonomic design, lifted and rotated
3.1.7 *Built-in couplant heater
3.1.8 Transducer interfaces:≥3, fully activated, transducer can be connected to any connectors freely
3.1.9 Interfaces: network, DVI, USB, S-video
3.1.10 Built-in DVD recorder
3.1.11 Harddisk: ≥ 1T
3.1.12 Support U disk or mobile HDD storage
3.1.13 Support black white printer and color printer
3.2 Transducer specification:
3.2.1 Support transducer type: convex array, linear array, phased array, endocavity, volume
3.2.2 Supports biopsy guide
3.2.3 Visual and adjustable transducer frequency ≥4, all modes of B ,color and doppler frequency are adjusted independently
3.2.4 Frequency range:
Convex array transducer frequency: 2.5-6.5 MHz
Phased array transducer frequency: 2.0-5.0 MHz
Linear array transducer frequency: 6.0-16.0 MHz
Endocavity transducer frequency: 5.0-11.0 MHz
Volume transducer frequency:3.0-6.0 MHz
3.2.5 Imaging modes:
Convex array transducer: B/M/CDI/PWD
Linear array transducer: B/M/CDI/PWD
Endocavity transducer: B/M/CDI/PWD
Phased array transducer: B/M/CDI/PWD/CWD
Volume transducer: B/M/CDI/PWD/3D/4D
Brand : TRUTH BIOMEDICAL
Features
1. On-line HDF
2. Self-checking function;
3. Carbonate dialysis;
4. Double needle dialysis;
5. Liquid level detector;
6. Bubble detector;
7. Blood leakage detector;
8. Temperature and electric conductivity monitoring;
9. Arterial pressure, venous pressure and transmembrane pressure monitoring;
10. Rolling blood pump;
11. Heparin pump;
12. Dehydration amount controlled by capacity;
13. Automatic disinfection cleaning program;
14. Stand-by power of blood pump in case of power failure;
15. Information display function of display screen.
Technical Specifications
PARAMETER
SPECIFICATION
Working Condition
Water input pressure
0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature
5℃~30℃
Working environment temperature
10℃~30℃ at relative humidity ≦70%
UF Rate
Flow range
0ml/h~4000ml/h
Resolution ratio
1ml
Precision
±30ml/h
Blood Pump & Substitution Pump
Blood pump flow range
10ml/min~600ml/min (diameter: 8mm or 6mm)
Substitution pump flow range
10ml/min~300ml/min (diameter 8mm or 6mm)
Resolution ratio
0.1ml
Precision
±10ml or 10% of reading
Heparin Pump
Syringe size
20, 30, 50ml
Flow range
0ml/h~10ml/h
Resolution ratio
0.1ml
Precision
±5%
Monitoring System & Alarm Setup
Venous pressure
-180mmHg ~ +600mmHg, ±10mmHg
Arterial pressure
-380mmHg ~ +400mmHg, ±10mmHg
TMP
-180mmHg ~ +600mmHg, ±20mmHg
Dialysate temperature
preset range 34.0℃~39.0℃
Dialysate flow
Less than 800 ml/min (Adjustable)
Substitution flow range
0-28 L/H (on line HDF)
Blood leak detection
Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate
Bubble detection
Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow
Conductivity
Acoustic-optic
Disinfection/Sanitize
Hot disinfection
Time: 30 minutes
Temperature: about 80℃, at flow rate 500ml/min
Chemical disinfection
Time: 30 minutes
Temperature: about 36℃~50℃, at flow rate 500ml/min
Chemical disinfection with heat
Time: 45minutes
Temperature: about 36℃~80℃, at flow rate 50ml/min
Rinse
Time: 10minutes
Temperature: about 37℃, at flow rate 800ml/min
Storage Environment
Storage temperature should be between 5℃~40℃, at relative humidity ≦80%
Power Supply
AC220V, 50Hz/60Hz, 10A
Input power
1500W
Back-up battery
30 minutes
Size &Weight
Size
380mmx400x1380mm (L*W*H)
Net Weight approx.
88KG
Gross Weight approx.
around 100KG
Package Size approx
650×690×1581mm (L x W x H)
Function
HDF, on-line BPM, Bi-cart and 2 pcs endotoxin filters
Optional Function
Online KT/V, LAN
Series : AN1000 ,Brand : TRUTH BIOMEDICAL
-Scope of Application: Adult, Child
-Gas Source: O2: 0.27-0.55Mpa
-Flow Meter: O2
-Flow Rate of Rapid Oxygen Supply: 25--75L/min
-Display: 5.7” LCD screen
-Ventilation Mode: IPPV, MANUAL
-Ventilation Tidal volume: 50--1500ml
I:E ratio: 2:1--1:8
Inspiratory trigger pressure: -1.0--2.0kPa
Pressure range: 1.0--6.0kPa
-Vaporizer: Among Halothane, Enflurane, Isoflurane and Sevoflurane,
one can be chosen
Series : AN1001 , Brand : TRUTH BIOMEDICAL
-Scope of Application: Adult, Child
-Gas Source: O2: 0.27-0.55Mpa; N2O: 0.27-0.55MPa.
-Flow Meter: O2, N20
-Flow Rate of Rapid Oxygen Supply: 25--75L/min
-Display: 5.7” LCD screen
-Ventilation Mode: IPPV, SIPPV, SIMV, PEE, MANUAL, SIGH
-Monitoring of Oxygen Concentration: 21%--100%
-Ventilation Tidal volume: 50--1500ml
I:E ratio: 2:1--1:8
Inspiratory trigger pressure: -1.0--2.0kPa
PEEP: 0--2.0kPa
Pressure range: 1.0--6.0kPa
SIGH: 1.5 times the inspiratory time
-Vaporizer: Among Halothane, Enflurane, Isoflurane and Sevoflurane,
one can be chosen
Series : AN1002 , Brand : TRUTH BIOMEDICAL
-Scope of Application: Adult, Child
-Gas Source: O2: 0.27-0.55Mpa; N2O: 0.27-0.55MPa.
-Flow Meter: O2, N20
-Flow Rate of Rapid Oxygen Supply: 25--75L/min
-Display: 10.4” color LCD touch screen
-Ventilation Mode: IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH (IMV,
VCV, PCV)
-Monitoring of Oxygen Concentration: 21%--100%
-Ventilation Tidal volume: 50--1500ml
I:E ratio: 2:1--1:8
Inspiratory trigger pressure: -1.0--2.0kPa
PEEP: 0--2.0kPa
Pressure range: 1.0--6.0kPa
SIGH: 1.5 times the inspiratory time (70-150 adjustable)
Inspiratory platform: 0--50%
-Vaporizer: Among Halothane, Enflurane, Isoflurane and Sevoflurane,
one can be chosen.
Series : AN1003
-Scope of Application: Adult, Child
-Gas Source: O2: 0.27-0.55Mpa; N2O: 0.27-0.55MPa.
-Flow Meter: O2, N20
-Flow Rate of Rapid Oxygen Supply: 25--75L/min
-Display: 5.7” LCD screen
-Ventilation Mode: IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
-Monitoring of Oxygen Concentration: 21%--100%
-Ventilation Tidal volume: 50--1500ml
I:E ratio: 2:1--1:8
Inspiratory trigger pressure: -1.0--2.0kPa
PEEP: 0--2.0kPa
Pressure range: 1.0--6.0kPa
SIGH: 1.5 times the inspiratory time
-Vaporizer: Among Halothane, Enflurane, Isoflurane and Sevoflurane,two can be chosen.
Series : AN1004
-Scope of Application: Adult, Child
-Gas Source: O2: 0.27-0.55Mpa; N2O: 0.27-0.55MPa.
-Flow Meter: O2, N20, Air
-Flow Rate of Rapid Oxygen Supply: 25--75L/min
-Display: 10.4” color LCD touch screen
-Ventilation Mode: IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH, IMV,
VCV, PCV
-Monitoring of Oxygen Concentration: 21%--100%
-Ventilation Tidal volume: 20--1500ml
I:E ratio: 4:1--1:8
Inspiratory trigger pressure: -1.0--2.0kPa
PEEP: 0--2.0kPa
Pressure range: 1.0--6.0kPa
SIGH: 1.5 times the inspiratory time, 70-150 adjustable
Inspiratory platform: 0--50%
-Vaporizer: Among Halothane, Enflurane, Isoflurane and Sevoflurane,
two can be chosen.
-With 12“ Patient Monitor (ECG, RESP, NIBP, SPO2, 2_TEMP,
PR/HR)-Option for patient monitor: ETCO2, IBP, touch sc
Series : AN1005
-8 inch TFT LCD screen, 800x480 pixels
-Tidal volume: 5-1500ml (Adult, Pediatric, Neonate)
-Gas supply: O2 , N2O, Air
-Mechanical Flowmeter: 6 flow tubes for 3 gas
-Ventilation Mode: VCV, PCV, SIMV-VC, SPONT/PSV, SIMV-PC,
Backup modes: PCV, Manual
-Lung mechanics parameters,3 waveforms, loops(P-V,V-F,P-F)
-Built-in electronic PEEP valve
-Circuit heated completely, By-pass,Included
-Reading lamp, 2 drawers, 4 wheels with brakes
-Built-in Li-on battery, 1 battery, 4800mAh
-Tow RJ-45, one USB, one Ethernet
-Vaporizer: Halothane, Isoflurane, Sevoflurane (standard with one
Chinese brand vaporizer)
Standard: Main unit, one Chinese brand vaporizer, O2 cell, Built-in Li-on
battery, Disposable adult anesthesia breathing circuit, O2/N2O/Air gas
pipelines, Hospital O2/N2O/Air joints
Options: Extra vaporizer (Chinese/Drager/Penlon/Northern), Touch
screen, Patient monitor, ETCO2, Suction module, Pediatric/Neonate
anesthesia breathing circuit, Spare cylinder yoke (O2, N2O), AGSS, Gas monitor module (CO2, AG), etc.
Series : AN1006
-Working mode: Manual
-Patient scope: from Pediatric to Adult (3kgs over)
-Tidal volume: 20-1500ml
-Gas supply: O2, O2+N2O, O2+Air, 0.25~0.65Mpa
-Working pressure: O2:0.3-0.4Mpa, N2O:0.3-0.4Mpa
-Flowmeters: O2: 0.1-10L/min, N2O: 0.1-10L/min
-O2 and N2O linkage device (ORC system), FiO2 ≥25%
-APL valve adjustment range: 0.5-6.0Kpa
-O2 Flush: 25-75L/min
-CO2 canister: 1000ml
Smal Vaporizer: Halothane, Enflurane, Isoflurane
Big Vaporizer: Halothane, Enflurane, Isoflurane, Sevoflurane
Optional:
Mobile Trolley , Anesthesia Ventilator