For Inquiry , Call us : +91 9836224820 , +918697635179 , Email : sales@truthbiomedical.com .
Hemodialysis Machine
Features
1. On-line HDF
2. Self-checking function;
3. Carbonate dialysis;
4. Double needle dialysis;
5. Liquid level detector;
6. Bubble detector;
7. Blood leakage detector;
8. Temperature and electric conductivity monitoring;
9. Arterial pressure, venous pressure and transmembrane pressure monitoring;
10. Rolling blood pump;
11. Heparin pump;
12. Dehydration amount controlled by capacity;
13. Automatic disinfection cleaning program;
14. Stand-by power of blood pump in case of power failure;
15. Information display function of display screen.
Technical Specifications
PARAMETER
SPECIFICATION
Working Condition
Water input pressure
0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature
5℃~30℃
Working environment temperature
10℃~30℃ at relative humidity ≦70%
UF Rate
Flow range
0ml/h~4000ml/h
Resolution ratio
1ml
Precision
±30ml/h
Blood Pump & Substitution Pump
Blood pump flow range
10ml/min~600ml/min (diameter: 8mm or 6mm)
Substitution pump flow range
10ml/min~300ml/min (diameter 8mm or 6mm)
Resolution ratio
0.1ml
Precision
±10ml or 10% of reading
Heparin Pump
Syringe size
20, 30, 50ml
Flow range
0ml/h~10ml/h
Resolution ratio
0.1ml
Precision
±5%
Monitoring System & Alarm Setup
Venous pressure
-180mmHg ~ +600mmHg, ±10mmHg
Arterial pressure
-380mmHg ~ +400mmHg, ±10mmHg
TMP
-180mmHg ~ +600mmHg, ±20mmHg
Dialysate temperature
preset range 34.0℃~39.0℃
Dialysate flow
Less than 800 ml/min (Adjustable)
Substitution flow range
0-28 L/H (on line HDF)
Blood leak detection
Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate
Bubble detection
Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow
Conductivity
Acoustic-optic
Disinfection/Sanitize
Hot disinfection
Time: 30 minutes
Temperature: about 80℃, at flow rate 500ml/min
Chemical disinfection
Time: 30 minutes
Temperature: about 36℃~50℃, at flow rate 500ml/min
Chemical disinfection with heat
Time: 45minutes
Temperature: about 36℃~80℃, at flow rate 50ml/min
Rinse
Time: 10minutes
Temperature: about 37℃, at flow rate 800ml/min
Storage Environment
Storage temperature should be between 5℃~40℃, at relative humidity ≦80%
Power Supply
AC220V, 50Hz/60Hz, 10A
Input power
1500W
Back-up battery
30 minutes
Size &Weight
Size
380mmx400x1380mm (L*W*H)
Net Weight approx.
88KG
Gross Weight approx.
around 100KG
Package Size approx
650×690×1581mm (L x W x H)
Function
HDF, on-line BPM, Bi-cart and 2 pcs endotoxin filters
Optional Function
Online KT/V, LAN