CREDIT & debit card ACCEPTED

Contact

Address - TRUTH BIOMEDICAL 

Awfis

Ecospace Business Park Premises , Rajarhat ,

2A, 6TH Floor,AA II, Kolkata - 700156

E-mail: info@truthbiomedical.com

info@truthempire.co

24 x 7 Contact number: +916289380385,

+918697635179 .

 

 

 Whatsapp : +918697635179 ,+91 6289380385 

 

  • LinkedIn Social Icon
  • Facebook
  • Twitter
  • YouTube
  • Instagram

© TRUTH BIOMEDICAL

Features

15” TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.

Air compressor runs stably with low noise, creates quiet environment for doctors and patients.

Integration breathing circuit design.

Multiple working modes such as volume control and pressure limit.

Multiple parameters monitoring interface to show clear parameter to the operator, allow operator know the patient conditions in all aspects.

Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision ETCO2, O2 concentration detection function included.

Electrical PEEP control

Breathing valve is disassembly and can be disinfected.

Safety

l Three levels alarm system, visual and sound alarm information.

l With multiple type of alarms, reminding and protection functions.

l Self-check before running, eliminate system mulfuction.

l Advanced power management control technology.

l With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.

l Separate design of electric and gas, keep safety running of ventilator.

Medical Ventilator

SKU: Series : NIRVANA 8008
$13,500.00 Regular Price
$12,825.00Sale Price
  •  

    The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.

     

  • Specifications

    Ventilation modes:

    IPPVA/CPCVSIMVSPONT/CPAPPSV

    Ventilator parameter ranges

     

    Tidal volume(Vt)

    ~ 2000mL

    Frequency (Freq)

    Oxygen concentration

    1bpm ~ 100 bpm

    21%-100%

    I/E

    4:11:8

    PEEP

    0cmH2O ~ 40 cmH2O

    Pressure Limit

    20 cmH2O ~ 100 cmH2O

    Monitored Parameters

     

    Frequency (Freq)

    0 /min ~ 100 /min

    Tidal volume(Vt)

    0 mL ~ 2500 mL

    MV

    Airway pressure

    Dynamic lung compliance testing

    ETCO2 Concentration

    0 L/min ~ 99 L/min

    0 cmH2O ~ 100 cmH2O

    1mL/cmH2O ~ 1000mL/cmH2O

    0mmHg ~ 152mmHg (0%-20%)

    Oxygen concentration

    15 % ~ 100 %

     

    Oscillographs display:

     

    P-T(pressure – time)

     

    F-T(flow – time)

     

    P-V loop (pressure – volume loop)

     

    V-T(volume – time )

     

    ETCO2-T (End-tidal CO2 - time)

     

     

     

    Alarms and protection

     

    The AC power failure alarm

    Power failure or no connection

    Internal battery backup low voltage alarm

    ≤11.3±0.3V

    No tidal volume

    No tidal volume within 6s

    High Minute Volume alarm

    Low Minute Volume alarm

    5L/min-99L/min

    1L/min-30L/min

    High Airway pressure alarm

    Low Airway pressure alarm

    High oxygen concentration alarm

    Low oxygen concentration alarm

    20cmH2O-100cmH2O

    0cmH2O-20cmH2O

    19%-100%

    18%-99%

    Continuous pressure alarm

    (PEEP+1.5cmH2O) over 16s

    Suffocation warning

    Fan error

    Oxygen deficit

                    5-60s

    Show on screen

    Show on screen

    The maximum limited pressure

    12.5 kPa

     

     

    Working conditions

     

    Gas source

    O2, AIR

    Pressure

    280kPa-600kPa

    Voltage

    220V±22V

    Power frequency

    50Hz ± 1Hz

    Input power

    900VA (with air compressor)

    250VA (without air compressor)

    Ventilation modes:

    IPPVA/CPCVSIMVSPONT/CPAPPSV

    Ventilator parameter ranges

     

    Tidal volume(Vt)

    ~ 2000mL

    Frequence (Freq)

    Oxygen concentration

    1bpm ~ 100 bpm

    21%-100%

    I/E

    4:11:8

    PEEP

    0cmH2O ~ 40 cmH2O

    Pressure Limit

    20 cmH2O ~ 100 cmH2O

    Monitored Parameters

     

    Frequence (Freq)

    0 /min ~ 100 /min

    Tidal volume(Vt)

    0 mL ~ 2500 mL

    MV

    Airway pressure

    Dynamic lung compliance testing

    ETCO2 Concentration

    0 L/min ~ 99 L/min

    0 cmH2O ~ 100 cmH2O

    1mL/cmH2O ~ 1000mL/cmH2O

    0mmHg ~ 152mmHg (0%-20%)

    Oxygen concentration

    15 % ~ 100 %

     

    Graphical display:

     

    P-T(pressure – time)

     

    F-T(flow – time)

     

    P-V loop (pressure – volume loop)

     

    V-T(volume – time )

     

    ETCO2-T (End-tidal CO2 - time)

     

     

     

    Alarm and protection

     

    The AC power failure alarm

    Power failure or no connection

    Internal battery backup low voltage alarm

    ≤11.3±0.3V

    No tidal volume

    No tidal volume within 6s

    High Minute Volume alarm

    Low Minute Volume alarm

    5L/min-99L/min

    1L/min-30L/min

    High Airway pressure alarm

    Low Airway pressure alarm

    High oxygen concentration alarm

    Low oxygen concentration alarm

    20cmH2O-100cmH2O

    0cmH2O-20cmH2O

    19%-100%

    18%-99%

    Continuous pressure alarm

    (PEEP+1.5cmH2O) over 16s

    Suffocation warning

    Fan error

    Oxygen deficit

                    5-60s

    Show on screen

    Show on screen

    The maximum limited pressure

    12.5 kPa

     

     

    Working conditions

     

    Gas source

    O2,AIR

    Pressure

    280kPa-600kPa

    Voltage

    220V ±22V

    Power frequency

    50Hz ± 1Hz

    Input power

    900VA (with air compressor)

    250VA (without air compreesor)