Defibrillator Monitor (AED and Manual)

- medical equipment online

SERIES : DISCIPLINE 15009

Technical specifications

Display

Screen Type: High-resolution display

Screen Size: 7 inches (1 7.7 cm) diagonally

Sweep Speed: 25mm/sec

Information: Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy

 

Defibrillator

Waveform: Biphasic

Energy Display: Monitor display indicates both selected and delivered energy

Charge Prompt Type: Voice and visual prompts

Electrode Impedance Measurement Range: 0-250 0hms

 

AED Mode

AED Function: Auto analyzes and charges x3 with programmable auto energy level selection, screen prompts, and voice prompts

Shockable Rhythms: Ventricular fibrillation, Ventricular tachycardia, QRS complex wave duration

Charge Control:  Control on device front panel, press key on paddle

 

Manual Mode

Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 Joule

Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor

 

ECG Monitoring

Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles

Lead Selection: Displayed on monitor, paddles, l, II, III, AVR, AVL, AVF, V

ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor

Heart Rate: 20-300BPM

Heart Rate Alarm: On/Off displayed on monitor, user-selectable

Smart Alarms: Beeper/Voice prompts indicate shockable rhythm

 

Sp02 Module

Measurement Range: 30-100%, +2% between 80%-90%, others + 5%

Alarm Range: User set high limit and low limit

Alarm Accuracy: +10% within setting values

Alarm Time Accuracy: Less than 12 sec

 

Recorder

Paper: 50mm thermal

Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay

Printing Method: High-resolution, thermal array print head

Print-out Modes: Manual or automatic, user-configurable

On/Off Control: Front panel and paddle

Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge

 

Battery

Type: Rechargeable, Ni-MH battery, 12V

Operating Time: For a new, fully charged battery 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions

DEFIBRILLATOR

SERIES : DISCIPLINE 15009

Technical Specifications

-Defibrillator type                   Manual, Synchronized, Asynchronized

-Out put waveform                Monophasic technology

-Energy accuracy                  <+1%

-Energy selection              0,3,5,7,10,20,30,50,100,200,300,360 Joule

(Nominal at a resistance of 50)

-Charging time                  Maximum 8 seconds to 360 Joule

-Paddles                Reusable external adult paddles

(Pediatric paddles integrated)

 

.Power Requirements

-AC Power supply                 110V, 60 Hz /220V, 50 Hz

-Vehicle Voltage          DC 12V

 

Internal Battery Backup

-Battery type             Rechargeable lead-acid battery/ lithium battery (optional)

-Charging time        Time-Minimum of 4 hours for full charging

-Battery charging   During AC Power Supply operation of the device.

-Charging /Low Battery Indication      Red LED

-Battery Capacity   100% of the battery will provide 120 mins of monitoring; and 30 discharges at 360 Joule

 

Display

-LED Dimensions     7’diagonal {155mm*88mm}

-Type                       High resolution true-color graphic LED

-Resolution                   480X234

 

ECG

ECG lead: I, II, III, AVR, AVL, AVF, V1-V6, GND

S-T segment analysis: -2.0-2.0mv

Arrhythmia analysis: yes

Protection: Withstand 4000vAc/50Hz voltage in isolation and work against electrosurgical interfere and defibrillation

 

Respiration

Measurement method: Thoracic impedance

 

Standard Parameter & Configuration

ECG/RESP/DEFIBRILLATOR

 

Optional

Recorder